Skip to main content

Clean Bottle

Home > Product > Clean Bottle

Clean Bottle

Our clean bottle is a clean container which can be used in various fields such as the chemicals for electronics, semiconductors, and LCDs, medical supplies, cosmetic raw materials, reagents, and foods.

Our clean bottle meets the UN standards. The test for the UN standards is divided into three different types of single containers, composite containers and combined, depending on its purpose.

※ As the recommendation of the UN on maritime transport of hazardous materials, all containers for dangerous goods transported between countries are to be used only those containers that meet UN standards through testing.

Clean Bottle Characteristics

  • Electronic Chemicals: Particles (0.1 to 0.3㎛) and elution ion (ppt)
  • Semiconductors & LCD Chemicals: Particles (0.1 to 0.3㎛), elution ion (ppt) and lighttight
  • Medical Supplies: No heavy metals, no eluted salts, and no organic elutions
  • Cosmetic Raw Materials: No heavy materials and no foreign substances
  • Reagents: Elution ion (lower ppm)
  • Foods: No heavy metals, foreign substances, smell and taste

Clean Grade of Clean Bottle

  • Our clean bottle does not cause impurities (particles) in contents and meets the quality standards established by the Japanese pharmaceutical administration.

Unit : EA/㎖

Particle Size
Cleanliness
0.2㎛ <9
0.3㎛ <2
0.5㎛ <0

※ Above data is our own data based upon our own test method. Please use only as a reference, as the results can not be guaranteed.

Metal Ion Elution Grade of Clean Bottle

  • Our clean bottle does not cause impurities (particles) in contents and meets the quality standards established by the Japanese pharmaceutical administration.

Unit : ppt

Metal ion
Elution degree
Na5 <
Mg5 <
Al5 <
K5 <
Ca5 <
Cr5 <
Mn5 <
Fe5 <
Ni5 <
Cu5 <
Zn5 <

※ Above data is our own data based upon our own test method. Please use only as a reference, as the results can not be guaranteed.

Chemical Stability

  • Our product has excellent chemical resistance as it is difficult for acid and alkali to penetrate.

◎ : Permitted     △ : Maximum     X : No Permission   [test temp 23℃]

Chemicals
Days
1 month3 month6 month12 month
Clean Bottle
H2O2X
HF
H2SO4
NaOH
Clean Drum
H2O2X
HF
H2SO4
NaOH

※ Above data is our own data based upon our own test method. Please use only as a reference, as the results can not be guaranteed.

UV Protection Ability of Clean Bottle

  • Our product prevents contents from being deteriorated due to UV.
Container
UV light transmissivity 400nm
UV light transmissivity 300nm
Clean Bottle t=1.402.33.3
Brown glass bottle t=3.073.87.0 or more

Barrier Ability of Clean Bottle

  • Our product prevents contents from being penetrated outside.

Weight Reduction Rate of Drugs (%) [Test Condition: 23℃ and keeping for six months]

Container
CHEMICAL
EGA
MEK
IPA
Clean Bottle0.040.250.09
Clean Drum0.040.250.09
Clean Barrier Bottle< 0.01< 0.01< 0.01
Glass Bottle< 0.01< 0.01< 0.01

▶ EGA : Ethylene glycol acetate, ▶ MEK : Methyl ethyl ketone, ▶ IPA : Isopropyl Alcohol

CLEAN BOTTLE ROHS

  • ROHS TEST REPORT
    ROHS : 6 hazardous materials regulated at EU